Possible
Causes |
|
Remedy |
| 1) |
Improper
type of filter element. |
1) |
Install a filter element
that has the correct micron
rating for the application. |
| 2) |
Plugged element. |
2) |
Clean or replace element. |
| 3) |
Filter change
interval too long. |
3) |
Decrease the time between
filter change periods. Add
bypass indicators to filters. |
| 4) |
Pressure
differential too high. |
4) |
Replace element with a high
pressure element and housing. |
| 5) |
Ruptured
element. |
5) |
See below: |
| |
| a) |
Stuck
bypass. |
| b) |
Improper
element. |
| c) |
High
pressure surging. |
|
|
| a) |
Repair or replace
bypass. |
| b) |
Replace element with
proper pressure rated
element. |
| c) |
Eliminate cause of
high pressure surging |
|
| 6) |
No element
installed. |
6) |
Install proper element. |